As of Release 4.0A, you can use the following new features in
results recording:
Table Control
Using the functions for table control, you can configure the
recording tables to suit your individual requirements.
Subscreen
With the help of subscreens, you can configure the header data for
the recording screens to suit your individual requirements. You can
replace a subscreen with the help of a customer enhancement.
'Summarized' recording view
You can record inspection results for all characteristics set for
summarized recording on the characteristic overview screen.
Recording configuration
With the help of the recording configuration, you can automate the
results recording function. You store the key for the recording
configuration in
Customizing.
You can also store all attributes as user parameters.
Forced closure
If you cannot close a characteristic or sample, the error message
list allows you to use the function for a forced
closure.
Attribute
You can confirm the attribute indicator and the measured value in a
single field.
Change documents
Changes to single values and classed values are recorded in change
documents.
Results data origin
With the results data origin, you can document the origin of a
result (for example, "value copied from certificate").
Digital signature
When you save the inspection results, the system checks the
identity of the inspector. For more information, refer to a
separate release
note that describes the digital signature.
Approval for inspection plan
If an inspection plan and the inspection lot is approved, you
cannot use the function unplanned