As of Release 4.0A, the following changes are valid with regard to PI sheet maintenance:
Possible entries for characteristics:
When calling the possible entries function (F4) on the value field of a characteristic, the following data is displayed on separate, consecutive dialog boxes:
Authorization for setting a PI sheet to technically complete
The new activity B2 (Set to technically complete) was included in the authorization object C_CRPI_BER (PI sheet). Users require this authorization to set a PI sheet to technically complete.
The enhanced authorization check requires that you revise the authorization of those users who set PI sheets to technically complete in your system; see Authorization Management.