locking properties

Definition

Controls the locking of orders when capacity leveling is called up in change mode.

Use

The orders are only locked when you change them on the planning table.
The orders in the pool are already locked when read. The orders dispatched are only locked when you change them.
Note the following special case: If an operation in an order is in the pool and another operation in this order is dispatched then the order is not locked.
All orders are already locked when they are read in.

In the order view the only orders locked when read in are those that you have selected on the initial capacity leveling screen. However, the system reads in additional orders to calculate the load of the capacities affected and displays them on the planning table; these are NOT locked.

Dependencies

The indicator locking properies is only active if the indicator change mode has been set.